Spin Column
HYUNDAI MICRO supplies spin columns to numerous domestic and overseas manufacturers of nucleic acid isolation and purification kit. Depending on the characteristics of the kits, there are various types of columns that can obtain high-yield and high-purity nucleic acid.
HM proposes optimal samples to achieve maximum extraction efficiency based on each manufacturer’s reagent composition. And can choose the best matching product through the testing. GenCro Spin column adopts the high quality silica membrane from a famous filter manufacturer and HM directly manages the production of the filter material to ensure the best efficiency.
In addition, use the high-quality plastic materials and produces them in automated facilities under the ISO 9001:2015 Quality Assurance System to maintain the stability of quality.
Mini Spin Column
 ▲ H4211G
 ▲ H4201G (Without Cap)
HM mini-spin column is compatible with a wide range of buffers from famous brands.
HYUNDAI MICRO has various formats of spin column that can cover from DNA to RNA. Available two types of tubes, with lid and without lid. Clear, blue, yellow, and purple are in four colors. Two types of O-ring, Flat and Sawtooth pattern are choosable depending oncharacteristics of reagent. Suitable for both Centrifuge and Vacuum method.
Supplied with a 2ml collection tube, and the columns for RNA extraction are individually packed and sterilized.
> RNase-/DNase-free
> Nonpyrogenic
> Nonsterile/Sterile(for RNA)
> Silica membrane
Pre-Filtration Column
When extracting the Total RNA, use before the Capsule type column(sterile).
During the Lysis process, removes the cell debris to prevent column blockage for improving the final RNA extraction efficiency. Only used for pre-filtration purposes, it doesn't have DNA /RNA binding capacity.
> RNase-/DNase-free
> Nonpyrogenic
> Nonsterile
> PE membrane filter
▲ H6211G(Pre-filtraton)
Product |
Cat no. |
Volume |
Color |
Filter |
Composition |
Packing |
Spin column |
H4211GC |
2ml(0.8ml) |
Clear |
Silica |
Spin column, Collection tube |
50ea/p.k |
Spin column(without cap) |
H4201GC |
2ml(0.8ml) |
clear |
Silica |
Spin column, Collection tube |
50ea/p.k |
Spin column(Bulk) |
H4211GCK |
2ml(0.8ml) |
Clear |
Silica |
Spin column, Collection tube |
500ea/p.k |
Spin column(Sterilized) |
H5111GC |
1ml(0.8ml) |
Clear |
Silica |
Spin column, Collection tube |
10ea/p.k |
Spin column (Pre-Filtration) |
H6211GC |
2ml(0.8ml) |
Clear |
PE |
Spin column, Collection tube |
50ea/p.k |
Collection tube |
H4200T |
2ml |
Clear |
- |
Collection tube |
50ea/p.k |
Spin column adaptor |
H4002A |
20ml |
Clear |
- |
Spin column adapter (for 2ml) |
5ea/p.k, 4p.k/box |
Midi Column
Easy to isolate / purificate high-yield Plasmid DNA into a midi scale, ideal for both Centrifuge and Vacuum method.
Supplied 15 ml conical tube with midi column and conical tubes are available for most centrifuges. Use only column, it is compatible with most Vacuum Manifolds.
> RNase-/DNase-free
> Nonpyrogenic
> Nonsterile
> Silica membrane
▲ H4210DC(15ml)
Maxi Column
Easy to isolate / purificate high-yield Plasmid DNA into a maxi scale, ideal for both Centrifuge and Vacuum method. Supplied 50 ml conical tube with midi column and conical tubes are available for most centrifuges. Use only column, it is compatible with most Vacuum Manifolds.
> RNase-/DNase-free
> Nonpyrogenic
> Nonsterile
> Silica membrane
▲ H4210AC(50ml)
Product |
Cat no. |
Volume |
Color |
Filter |
Composition |
Packing |
Midi column |
H4210DC |
15ml |
Clear |
Silica |
15ml tube + Midi column |
5ea/p.k, 4p.k/box |
Maxi column |
H4210AC |
50ml |
Clear |
Silica |
50ml tube + Midi column |
4ea/p.k, 5p.k/box |
96-well binding plate
Up to 96 samples can be easily isolated and purified at the same time.
Use high-quality Silica membrane, ensure the high-yield and stability. (Collection plate is not included.)
> RNase-/DNase-free
> Nonpyrogenic
> Nonsterile
> Silica membrane
▲ H4201WC
Product |
Cat no. |
Volume |
Color |
Filter |
Composition |
Packing |
96-well binding plate |
H4201WC |
1.5ml/well |
Clear |
Silica |
96-well binding plate |
1ea/p.k, 6p.k/box |
Product selection guide
HM offers a wide range of options for manufacturers of nucleic acid purification kit.
Optimal column for your reagent can be selected by the following list.
Step 1. Column Types
Product type |
Standard |
Color |
Column with cap |
2ml(0.8ml) |
Natural
Violet
Blue
Yellow
|
Column with out cap |
2ml(0.8ml) |
Medi column |
15ml |
Maxi column |
50ml |
96-well plate |
1.5ml/well |
※ You can choose the color.
Step 2. O-Ring
O-Ring type |
color |
Sawtooth-pattern |
Natural
Green
Blue
Red
Violet
|
Flat-pattern |
Step 3. Filter Material
Filter layer |
Application |
Samples will be
provided for the
testing for each
application.
HM will provide the
different filter latered
spin columns for the
maximum efficiency
of manufacturer's
reagent composition.
|
Plasmid prep kit |
Genomic prep kit |
PCR Purification kit |
Gel Purification kit |
Total RNA prep kit |
Plant DNA prep kit |
Blood RNA prep kit |
Bacteria DNA prep kit |
Viral Nucleic acid prep kit |
Step 4. Package
- Select Options
- Package material
- Package design
- Standard packing unit
(Individual, Bulk, Small quantity packing)
- Sterilization
- ▼
- Final decision
※ The choice can be limited under few conditions.
Compatible test_Supplier “Q” and spin column.
1. Genomic DNA Extraction
1-1. Mammalian cell culture< Sample : HeLa cell (1x106 cell) >
- Yield(㎍)
- 8.99
- 7.87
- 8.34
- 7.23
- 8.01
- 7.72
- 8.29
- 7.83
- A260/A280
- 2.08
- 2.05
- 2.06
- 2.03
- 2.01
- 2.00
- 2.00
- 2.00
1-2. Blood< Sample : Human blood (100µℓ) >
- Yield(㎍)
- 1.82
- 1.98
- 1.79
- 2.23
- 2.26
- 1.87
- 1.75
- 1.76
- A260/A280
- 1.88
- 1.99
- 1.86
- 1.89
- 1.89
- 1.94
- 1.89
- 1.89
1-3. Plant< Sample : Brassica oleracea (100mg) >
- Yield(㎍)
- 5.03
- 4.65
- 5.77
- 4.40
- 6.33
- 6.38
- 5.74
- 5.30
- A260/A280
- 1.88
- 1.08
- 1.81
- 1.78
- 1.80
- 1.81
- 1.82
- 1.84
1-4. Animal Tissue< Sample : Mouse kidney (20mg) >
- Yield(㎍)
- 18.38
- 21.77
- 25.76
- 21.80
- 14.62
- 15.98
- 13.64
- 16.53
- A260/A280
- 1.92
- 1.92
- 1.90
- 1.93
- 1.94
- 1.94
- 1.95
- 1.92
1-5. Bacterium< Sample : E. coli (5x108 cell) >
- Yield(㎍)
- 4.6
- 4.12
- 4.14
- 4.62
- 3.62
- 4.32
- 4.06
- 4.2
- A260/A280
- 2.03
- 1.97
- 1.93
- 1.94
- 1.96
- 1.92
- 1.96
- 1.94
2. Plasmid DNA Extraction & Fragment DNA Purification
2-1. High-copy plasmid< Sample : Puc19 plasmid, 2ml culture >
- Yield(㎍)
- 1.63
- 1.71
- 1.32
- 1.11
- 1.74
- 1.91
- 2.06
- 1.99
- A260/A280
- 1.90
- 1.89
- 1.88
- 1.78
- 1.89
- 1.84
- 1.89
- 1.90
2-2. Low-copy plasmid< Sample : Pet28b plasmid, 2ml culture >
- Yield(㎍)
- 1.21
- 1.14
- 1.45
- 1.27
- 1.05
- 0.78
- 1.50
- 1.30
- A260/A280
- 1.92
- 1.82
- 1.88
- 1.88
- 1.86
- 1.85
- 1.85
- 1.90
2-3. PCR product< Sample : 500bp PCR product >
- Yield(㎍)
- 1.50
- 1.53
- 1.47
- 1.49
- 1.64
- 1.57
- 1.46
- 1.41
- A260/A280
- 1.88
- 1.98
- 1.97
- 1.95
- 1.91
- 1.88
- 1.91
- 1.89
2-4. Gel purification< Sample : 500bp PCR product >
- Yield(㎍)
- 1.07
- 1.13
- 1.15
- 1.11
- 1.12
- 1.20
- 1.13
- 1.13
- A260/A280
- 1.92
- 1.97
- 1.94
- 1.90
- 1.86
- 2.28
- 1.91
- 1.97
3. RNA Extraction
3-1. Mammalian cell culture< Sample : HeLa cell (1x106 cell) >
- Yield(㎍)
- 15.40
- 16.23
- 19.69
- 17.21
- 18.01
- 17.61
- 15.33
- 18.55
- A260/A280
- 2.06
- 2.06
- 2.06
- 2.07
- 2.06
- 2.07
- 2.07
- 2.05
3-2. Plant< Sample : Brassica oleracea (100mg) >
- Yield(㎍)
- 40.35
- 39.55
- 45.69
- 66.28
- 33.77
- 34.02
- 58.09
- 43.08
- A260/A280
- 2.06
- 2.08
- 2.05
- 2.07
- 2.06
- 2.07
- 2.07
- 2.05
3-3. Bacterium< Sample : E. coli (1x108 cell) >
- Yield(㎍)
- 4.42
- 4.50
- 4.85
- 5.05
- 5.47
- 5.88
- 5.04
- 3.62
- A260/A280
- 2.06
- 2.08
- 2.05
- 2.07
- 2.06
- 2.07
- 2.07
- 2.05
3-4. Animal Tissue< Sample : Mouse kidney (20mg) >
- Yield(㎍)
- 52.39
- 31.09
- 58.91
- 36.50
- 46.51
- 43.32
- 49.20
- 46.00
- A260/A280
- 2.06
- 2.08
- 2.05
- 2.07
- 2.06
- 2.07
- 2.07
- 2.05
96 Deep Well Plate
HM Deep-Well plates are ideal for sample storage,High Throughput Screening (HTS), cell and tissue culture, and other applications. The well is indexed with alphabets and numbers for easy identifying samples. And the bottom part of the plate is designed to be easily stacked and stored. Produced with high quality virgin polypropylene, it is stable and resistant to various chemicals. so, has no harmful effect on the stored samples.
96 deep well plate
Indexing
The well is indexed with alphabets and numbers for easy identifying samples.
High quality virgin PP
Produced with high quality virgin polypropylene, it has no harmful effect on the stored samples.
Suitable for automation equipment
Designed to meet SBS standards, it is suitable for use in automated sample processors.
96 Deep Well Plate
Made of Virgin Polypropylene, it has excellent chemical resistance and is ideal for collection plates.
It is also suitable for storage plates for compounds, specimens, or molecular biology.
And the round well floor reduces liquid residual.
Alphanumeric indexing for each wells are enabling quick and easy sample identification.
Each well has a protruding shape, allowing safe sealing with film and sealing mats, and prevents contamination between the wells.
Suitable for use with large quantity and automatic sample processor equipment in accordance with SBS standards.
HTS(High Throughput Screening) friendly and compatible with various liquid processing equimpents.
- > Alphanumeric Indexing
- > SBS Standard format
- > RNase-/DNase-free
- > Nonpyrogenic
- > Virgin polypropylene
Product |
Cat no. |
Color |
Material |
Composition |
Packing |
96 deep well plate |
HB920C96 |
Clear |
Virgin PP |
Plate only |
100 plate/box |
|